Scalar i7 RAPTOR |
Scalar i6000 |
Scalar i6 |
Scalar i3 |
Number of Slots |
100 to 2,016 |
100 to 14,100 |
50 to 800 |
25 to 800 |
System Capacity Range (TB)
|
LTO-9 (native / compressed) |
1,800 to 36,288 / 4,500 to 90,720 |
1,800 to 253,800 / 4,500 to 634,500 |
900 to 14,400 / 2,250 to 36,000 |
450 to 14,400 / 1,125 to 36,000 |
LTO-8 (native / compressed) |
1,200 to 24,192 / 3,000 to 60,480 |
1,200 to 169,200 / 3,000 to 423,000 |
600 to 9,600 / 1,500 to 24,000 |
300 to 9,600 / 750 to 24,000 |
LTO-7 (native / compressed) |
600 to 12,096 / 1,500 to 30,240 |
600 to 84,600 / 1,500 to 211,500 |
300 to 4,800 / 750 to 12,000 |
150 to 4,800 / 375 to 12,000 |
Number of Drives |
1 – 20 |
1 – 192 |
1 – 24 |
1 – 24 |
Drive Types Supported |
Full-Height (FH) LTO Drives |
Full-Height (FH) LTO Drives |
Full-Height (FH) LTO Drives |
Half-Height (HH) LTO Drives |
How System Scales |
Scales by adding magazines 100-slot CoD licensing |
Scales linearly up to 20 racks 100-slot CoD licensing |
Scales vertically in rack up to 48U in 6U increments and 25-slot CoD licensing |
Scales vertically in rack up to 48U in 3U increments and 25-slot CoD licensing |
Module Form Factor |
Full Rack |
Full Rack |
Rackmount 6U |
Rackmount 3U |
Minimum Size |
One Module (One Full Rack) |
One Module (One Full Rack) |
One Module (6U) |
One Module (3U) |
Maximum Size |
One Module (One Full Rack) |
Twenty Modules |
Eight Modules (48U) |
Sixteen Modules (48U) |
Deployment |
Free-standing |
Free-standing |
Rack-mounted |
Rack-mounted |
Operation
|
Inventory Speed |
TBD |
TBD |
For most modules, 1 minute 12 seconds; four modules <5 minutes |
Ranges from approx. 1 minute to 6 minutes, depending on the configuration |
Connectivity |
Drive Interfaces |
8 Gb Fibre Channel; 12 Gb SAS (LTO-9 only) |
8 Gb Fibre Channel; 12 Gb SAS (LTO-9 only) |
8 Gb Fibre Channel; 12 Gb SAS (LTO-9 only) |
8 Gb Fibre Channel and 6/12 Gb SAS |
Management Interface |
Dual 1 GbE |
Library Interface |
Bridged through drive for data; 1 GbE with remote GUI and RESTful Web Services for library mgmt |
Import/Export Options
|
I/E Stations |
Configurable, 0-56 slots |
Configurable, 0-56 slots |
CM includes 24-slot I/E Station; Additional 24-slot and 72-slot I/E Stations available |
One I/E Station, configurable in 5-slot increments |
Max I/E Station Slots |
56 slots |
56 slots |
240 slots per partition |
240 slots |
Bulk Load/Unload Options |
by magazine |
Using HDEM |
by magazine |
by magazine |
Extended I/E |
Supported |
Not Supported |
Auto-import |
Export Redirect |
Dimensions (H x W x D)
|
Control Module |
90.2 in x 23.9 in x 54.3 in (229 cm x 60.6 cm x 138 cm) |
77.4 in × 24.3 in × 38.3 in (196.6 cm × 61.7 cm × 97.4 cm) |
10.4 in x 17.4 in x 36.4 in (26.4 cm x 44.1 cm x 92.45 cm) |
5.2 in x 17.4 in x 36.4 in (13.2 cm x 44.1 cm x 92.45 cm) |
Expansion Module |
N/A |
77.4 in × 23.6 in × 38.3 in (196.6 cm × 59.9 cm × 97.4 cm) |
10.4 in x 17.4 in x 36.4 in (26.4 cm x 44.1 cm x 92.45 cm) |
5.2 in x 17.4 in x 36.4 in (13.2 cm x 44.1 cm x 92.45 cm) |
Parking Module |
N/A |
77.4 in × 23.6 in × 38.3 in (196.6 cm × 59.9 cm × 97.4 cm) |
N/A |
N/A |
Reliability and Availability
|
MSBF |
Greater than 3 million |
Greater than 3 million |
Greater than 2 million |
Greater than 2 million |
MTTR |
5 minutes or less |
20 mins, 10 mins for Dual Robot replacement |
30 minutes |
30 minutes |
Electrical |
200-240 VAC or 240/380 VDC |
0-240 VAC, 2-24 kVA; -48 VDC, <1 kVA per module |
100 VAC to 240 VAC, 50 Hz to 60 Hz |
100 VAC to 240 VAC, 50 Hz to 60 Hz |
Power |
2N power included, 80 PLUS Titanium certified power supplies |
2N power included, 80 PLUS Titanium certified power supplies |
Control and Expansion Modules: Optional 2N power / 80 PLUS® Gold certified power supplies; HD Expansion Modules: Optional 2N power / 80 PLUS® certified power supplies |
Optional 2N power / 80 PLUS® Gold certified power supplies |
Dual Robotics |
No |
Yes |
No |
Rack Installation Requirements |
N/A |
N/A |
Library must be installed in a standard 19-inch four-post rack enclosure; rack must support product depth of 36.4 in (92.5 cm) |
Module Upgrades |
N/A |
Requires Quantum Installation |
Any module may be added in <30 minutes; all components are customer installable |
نقد و بررسیها
Clear filtersهنوز بررسیای ثبت نشده است.